The Ideal Clausius-Clapeyron equation assumes constant ΔHvap and ideal gas behavior. Real fluids deviate, especially near the critical temperature. Use the buttons on the left to switch between these models.
1. Ideal Clausius-Clapeyron
Assumes the enthalpy of vaporization (ΔHvap) is constant and the vapor behaves as an ideal gas.
ln(P/P₀) = -(ΔHvap / R) · (1/T - 1/Tb)
Plotting ln(P) vs 1/T yields a perfectly straight line with slope -ΔHvap/R.
2. Watson Correlation
Recognizes that ΔHvap decreases as temperature approaches the critical point (Tc).
Because the enthalpy changes with temperature, the linearized plot will curve slightly at higher temperatures.
3. Antoine Equation (Empirical)
A highly accurate empirical correlation used widely in engineering. It uses fitted constants (A, B, C) to account for non-ideal gas behavior and liquid volume effects. Note: P is in mmHg and T is in °C for these constants.
log10(P) = A - B / (T + C)
The constants for this simulation have been fitted to ensure the curve passes exactly through the normal boiling point (1 atm) and closely matches the ideal curve at low temperatures, but diverges realistically near the critical point.